USA Federal Standard 209E(1992)

Air cleanliness class

Particle size (μm)

0.1

0.2

0.3

0.5

5.0

1

35.0

7.50

3.00

1.00

NA

10

350

75.0

30.0

10.0

NA

100

NA

750

300

100

NA

1000

NA

NA

NA

1000

7.0

10000

NA

NA

NA

10000

70.3

100000

NA

NA

NA

100000

700

Unit: amounts of particle per cubic foot

 The Air cleanliness standard of clean room (area) of the pharmaceutical industry

Air cleanliness class

Maximum amounts of particle per square meter

Maximum amounts of animalcule

≥0.5μm

≥5μm

Amounts of airborne microbe per square meter

Amounts of colony forming microbe per Petri dish in 30min

100

3500

0

5

1

10000

350,000

2,000

100

3

100000

3,500,000

20,000

500

10

300000

10,500,000

61,800

NA

15

It is published by State Food and Drug Administration (SFDA) on Aug, 1st, 1999

 The degree of cleanliness in the clean room and clean area

Air cleanliness class (N)

Equals or exceeds the max density of the dust size(pc/m3)

0.1μm

0.2μm

0.3μm

0.5μm

1μm

5μm

1

10

2

 

 

 

 

2

100

24

10

4

 

 

3

1000

237

102

35

8

 

4

10000

2370

1020

352

83

 

5

100000

23700

10200

3520

832

29

6

1000000

237000

102000

35200

8320

293

7

 

 

 

352000

83200

2930

8

 

 

 

3520000

832000

29300

9

 

 

 

35200000

8320000

293000

Code for design of clean room GB 50073-2001

 Checking list of some countries’ air cleanliness based on the particle sizes ≥0.5μm

AmountsPer m3 ≥0.5μm

ISO
14644-1
(1999)

US
209E
(1992)

US
209D
(1988)

EEC
GGMP
(1989)

FRANCE
AFNOR
(1981)

GERMAN
VDI 2083
(1990)

JAPAN
JAOA
(1989)

1

-

-

-

-

-

-

-

3.5

2

-

-

-

-

0

2

10.0

-

M1

-

-

-

-

-

35.3

3

M1.5

1

-

-

1

3

100

-

M2

-

-

-

-

-

353

4

M2.5

10

-

-

2

4

1,000

-

m3

-

-

-

-

-

3,530

5

m3.5

100

A+B

4,000

3

5

10,000

-

M4

-

-

-

-

-

35,300

6

M4.5

1,000

1,000

-

4

6

100,000

-

M5

-

-

-

-

-

353,000

7

M5.5

10,000

C

400,000

5

7

1,000,000

-

M6

-

-

-

-

-

3,530,000

8

M6.5

100,000

D

4,000,000

6

8

10,000,000

-

M7

-

-

-

-

-

 Class of clean operating room (vacant state or static state)

Class

Name of operating room

The maximum average density of colony forming (airborne) microbe

Air cleanliness class

Operating area

Surrounding area

Operating area

Surrounding area

I

Special clean operating room

0.2/30min·φ90 Petri dish(5/m3)

0.4/30min·φ90Petri dish(10/m3

100class

1000class

II

Standard Clean operating room

0.75/30min·φ90Petri dish(25/m3

1.5/30min·φ90Petri dish(50/m3

1000class

10000class

III

Common clean operating room

2/30min·φ90Petri dish(75/m3

4个/30min·φ90Petri dish(150/m3

10000class

100000class

IV

Clean operating room

5/30min·φ90Petri dish(175/m3

300000class

Architecture technical code for hospital clean operating department

 Class of clean supplementary operating room (vacant state or static state)

Class

The maximum average density of colony forming (airborne) microbe

The maximum density of microbe on surface(amounts / m3)

Air cleanliness class

I

Partial: 0.2 / 30min·φ90 Petri dish (5 /m3)Others: 0.4 / 30min·φ90 Petri dish (10 /m3)

5

Partial: Class 100
Class 1000

II

1.5/30min·φ90Petri dish(50/m3

5

Class 10000

III

4/30min·φ90Petri dish(150/m3

5

Class 100000

IV

5/30min·φ90Petri dish(175/m3

5

Class 300000

Note: The maximum average density of airborne microbe method should be used the datum in the parenthesis. The microbe density was tested directly, not obtained by conversing colony forming microbes with airborne units.

‘Architectural and Technical Code for Biosafety Laboratories’ GB50346-2004

 The main technical index of main lab

Class

Air cleanliness class

Minimum air change rate
(times/hour)

The minimum negative pressure to the connected outward rooms
(Pa)

Temperature

Relative humidity
%

Noise dB(A)

Minimum illumination
lx

I

--

Openable windows

--

18--28

≤70

≤60

200

II

--

Openable windows

--

18--27

30--70

≤60

300

III

7 or 8

15 or 12

-10

18--25

30--60

≤60

350

IV

7 or 8

15 or 12

-10

18--24

30--60

≤60

350

Note:
 1.The minimum negative pressure of the main lab BSL-3 is no less than -30Pa, the minimum negative pressure of the main lab BSL-4 is no less than -40Pa.
 2.The minimum negative pressure of the main lab ABSL-3 is no less than -40Pa, meanwhile its dissecting room is no less than -50Pa; The minimum negative pressure of the main lab ABSL-4 is no less than -50Pa, at the same time its dissecting room is no less than -60Pa.
 3.The noises of biosafety cabinet, animal isolation are not including in this table, if the noises of the equipments are included, they are no more than 68dB(A)
 4.The parameter of biosafety cabinet lab should conform to‘Laboratory animal--Requirements of environment and housing facilities’GB14925.

‘Architectural and Technical Code for Biosafety Laboratories’ GB50346-2004

 The main technical index of supplementary biosafety laboratories about class3 and class4

Room name

Air cleanliness class

Minimum air change rate
(times/hour)

The minimum negative pressure to the outward connected rooms (Pa)

Temperature

Relative humidity
%

Noise dB(A)

Minimum illumination lx

Buffer room of the main lab

7 or 8

15 or 12

-10

18--27

30--70

≤60

200

Separated passage

7 or 8

15 or 12

-10

18--27

30--70

≤60

200

Preparing room

7 or 8

15 or 12

-10

18--27

30--70

≤60

200

The second locker room

8

10

-10

18--26

--

≤60

200

Buffer room of the second locker room

8

10

-10

18--26

--

≤60

200

Chemistry shower

--

4

-10

18--28

--

≤60

150

The first locker room(put on or take off close or uniform)

--

--

--

18--26

--

≤60

150

Note: if biosafety cabinet was installed, the maximum noise must not be less than 68dB(A).

‘Architectural and Technical Code for Biosafety Laboratories’ GB50346-2004

 The checking table of air filters’ class in some countries